Model | UM-5DL |
Measuring range | 0.65-508 mm (0.025 - 20.00 inches) depends on the probe used, the material to be tested, and the surface condition. |
Penetration coaSting function | YES |
Working principle | Ultrasonic Pulse/Echo Method and Echo/Echo Using Dual Crystal Probe |
Standard mode range | 0.6 to 508 mm (0.025 to 20.00 inches) depends on the probe used, the material to be tested, and the surface condition. |
Coating mode range | 3-80mm depends on the probe, material, surface condition and temperature used. |
Storage | store 400 files, 100,000 thickness values and 1000 A and B scanning waveforms. |
Measurement resolution | 0.01 or 0.1mm (0.001 or 0.01in) |
Unit | Millimeters or inches |
Display | 2.4QVGA (320×240) color OLED screen with contrast ratio of 10000:1 |
Gain | Real-time adjustable |
Repeatability | ±0.05mm |
Calibration mode | One-point calibration, two-point calibration |
Measurement error | 0.05 mm (below 25 mm) ; ±0.2% H (below 100mm) ;(0.5% h+0.01) (more than 100 mm) Note: h is the thickness of the measured object |
The measurement update rate | 4HZ, 8HZ and 16HZ per second are optional. |
The sound speed range of the material | 500-9999m/s,0.0179-0.3937in/us |
Alarm function | The maximum/minimum alarm, alarm dynamically change the thickness reading color |
Display mode | Thickness value mode, minimum/maximum capture mode, difference/reduction rate mode |
V path correction | Automatic A-range correction to compensate nonlinearity of bimorph probe |
Language | Chinese, English, Japanese, German and French are available |
Power supply | two AA batteries |
Operating time | Two AA batteries for more than 35 hours |
Automatically shut down | Optional 5, 10, 20 minutes after no operation automatically shut down, or only manually shut down |
Working temperature | -10℃ ~+50℃, with special requirements up to -20℃ |
Size | 153*76*37mm |
Weight | 280g (including battery) |
Standard configuration | Thickness gauge host, standard probe, instrument box, two alkaline batteries, coupling agent, operation manual, certificate of approval and packing list |
Optional accessories | Rubber jacket; A variety of selectable probes; Step test block for calibration; Coupling agent and high temperature coupling agent |
Configuration list |
Mainframe | 1 |
Coupling agent | 1 |
Probe | 1 |
Battery | 2 |
Packing document | 1 |
Instrument seal box | 1 |
Data line | 1 |
Communication software | 1 |
Note: If send it by air, not including batteries, it’s an empty bottle for Coupling agent. |